- Energy-classification A
- Steady start
- Stable illumination as the supply voltage varies in the range 230-240VAC
- High efficiency
- PF > 0.55
- Wide range of ambient temperatures: -10°C to +40°C
- Type of filament: T2
- Lifetime 10,000 hours
- Number of switchings on ≥ 30,000 times
- Colour temperature 2700K
- Content of Hg < 1.5mg
- Run-up time <1.5s (for power of 7–9W), <1.0s (for power of 11–23W)
- Luminous flux conservation 70%
- Do not work with lighting dimmers
Power [W] |
Base | Product code | Luminous flux [lm] | Incandescent lamp equivalent
[W] |
The time taken for the lamp to warm up to 60% of full luminous flux (sec) | Input current
[mA] |
Power consumption in kWh per 1,000h | Length [mm] |
Diameter [mm] |
7.0 |
E14 | C-SLT2FS-7W-E14 | 390 | 37 | <40 | 55 | 7 | 87 | 42 |
9.0 |
E14 | C-SLT2FS-9W-E14 | 510 | 45 | <40 | 62 | 9 | 89 |
42 |
11.0 |
E14 | C-SLT2FS-11W-E14 | 670 | 55 | <40 | 84 | 11 | 103 |
42 |
13.0 |
E14 | C-SLT2FS-13W-E14 | 820 | 65 | <40 | 94 | 13 | 108 |
42 |
7.0 |
E27 | C-SLT2FS-7W-E27 | 390 | 37 | <40 | 57 | 7 | 85 |
42 |
9.0 |
E27 | C-SLT2FS-9W-E27 | 510 | 45 | <40 | 64 | 9 | 87 |
42 |
11.0 |
E27 | C-SLT2FS-11W-E27 | 670 | 55 | <40 | 82 | 11 | 100 |
42 |
13.0 |
E27 | C-SLT2FS-13W-E27 | 820 | 65 | <40 | 96 | 13 | 104 |
42 |
15.0 |
E27 | C-SLT2FS-15W-E27 | 960 | 74 | <40 | 98 | 15 | 110 |
42 |
18.0 |
E27 | C-SLT2FS-18W-E27 | 1155 | 86 | <40 | 126 | 18 | 109 |
54 |
20.0 |
E27 | C-SLT2FS-20W-E27 | 1270 | 93 | <40 | 135 | 20 | 115 |
54 |
23.0 | E27 | C-SLT2FS-23W-E27 | 1500 | 106 | <40 | 156 | 23 | 121 |
54 |
- Energy-classification A
- Steady start
- Stable illumination as the supply voltage varies in the range 230-240VAC
- High efficiency
- Wide range of ambient temperatures -10°C to +40°C
- Power factor of the lamp PF ≥ 0.55
- Type of filament: T2
- Lifetime 10,000 hours
- Number of switchings on ≥ 30,000 times
- Colour temperature 2700K
- Content of Hg < 1.5mg
- Run-up time <1.5s
- Luminous flux conservation 70%
- Do not work with lighting dimmers
Power [W] |
Base | Product code | Luminous flux [lm] | Incandescent lamp equivalent
[W] |
The time taken for the lamp to warm up to 60% of full luminous flux (sec) | Input current
[mA] |
Power consumption in kWh per 1,000h | Length [mm] |
Diameter [mm] |
7.0 |
E14 | C-SLCA-7W-E14 | 300 | 30 | <40 | 49 | 7 | 108 | 38 |
9.0 |
E14 | C-SLCA-9W-E14 | 430 | 40 | <40 | 64 | 9 | 118 |
38 |
7.0 |
E27 | C-SLCA-7W-E27 | 300 | 30 | <40 | 51 | 7 | 105 |
37 |
9.0 | E27 | C-SLCA-9W-E27 | 430 | 40 | <40 | 62 | 9 | 115 |
37 |
- Energy classification A
- Steady start
- Stable illumination as the supply voltage varies in the range 230-240VAC
- High efficiency
- Wide range of ambient temperatures -10°C to +40°C
- Power factor of the lamp PF ≥ 0.55
- Type of filament: T2
- Lifetime 10,000 hours
- Number of switchings on ≥ 30,000 times
- Colour temperature 2700K
- Content of Hg < 1.5mg
- Run-up time <1.5s (for fluorescent lamps 7W–9W) and <1.0s (for fluorescent lamps 11W–23W)
- Luminous flux conservation 70%
- Do not work with lighting dimmers
Power [W] |
Base | Product code | Luminous flux [lm] | Incandescent lamp equivalent
[W] |
The time taken for the lamp to warm up to 60% of full luminous flux (sec) | Input current
[mA] |
Power consumption in kWh per 1,000h | Length [mm] |
Diameter [mm] |
7.0 |
E27 | C-SLB-7W-E27 | 300 | 30 | <40 | 55 | 7 | 100 |
55 |
9.0 |
E27 | C-SLB-9W-E27 | 430 | 40 | <40 | 64 | 9 | 111 |
55 |
11.0 |
E27 | C-SLB-11W-E27 | 570 | 45 | <40 | 75 | 11 | 111 |
55 |
15.0 |
E27 | C-SLB-15W-E27 | 800 | 60 | <40 | 108 | 15 | 125 |
60 |
- Energy-classification A
- Steady start
- Stable illumination as the supply voltage varies in the range 230-240VAC
- High efficiency
- Power factor of the lamp PF ≥ 0.57
- Wide range of ambient temperatures -10°C to +40°C
- Type of filament: T2
- Lifetime 15,000 hours
- Number of switchings on ≥ 30,000 times
- Colour temperature 2700K (and 4000K for 18W and 23W)
- Content of Hg ≤ 2.5mg
- Run-up time <1.5s (for fluorescent lamps 7W–9W) and <1.0s (for fluorescent lamps 11W–23W)
- Luminous-flux conservation 70%
- Does not work with lighting dimmers
Power [W] |
Base | Product code | Luminous flux [lm] | Incandescent lamp equivalent
[W] |
The time taken for the lamp to warm up to 60% of full luminous flux (sec) | Input current
[mA] |
Power consumption in kWh per 1,000h | Length [mm] |
Diameter [mm] |
7.0 |
E14 | C-1407-0G | 430 | 40 | <30 | 60 | 7 | 83 |
46 |
9.0 |
E14 | C-1409-0G | 580 | 50 | <30 | 70 | 9 | 88 |
46 |
11.0 |
E14 | C-1411-0G | 730 | 59 | <30 | 85 | 11 | 94 |
46 |
13.0 |
E14 | C-1413-0G | 880 | 69 | <30 | 105 | 13 | 100 |
46 |
7.0 |
E27 | C-1707-0G | 430 | 40 | <30 | 60 | 7 | 83 |
46 |
9.0 |
E27 | C-1709-0G | 580 | 50 | <30 | 70 | 9 | 88 |
46 |
11.0 |
E27 | C-1711-0G | 730 | 59 | <30 | 85 | 11 | 94 |
46 |
13.0 |
E27 | C-1713-0G | 880 | 69 | <30 | 105 | 13 | 100 |
46 |
18.0 |
E27 | C-1718-0G | 1140 | 85 | <40 | 140 | 18 | 112 |
59 |
20.0 |
E27 | C-1720-0G | 1220 | 90 | <30 | 150 | 20 | 112 |
59 |
23.0 |
E27 | C-1723-0G | 1400 | 100 | <30 | 175 | 23 | 117 |
59 |
-
- Unlimited number of on/off cycles
- Works with motion sensors.
- Can be mounted in stairwells
- Lifetime 15,000 hours
- Energy-classification A
- Steady start
- Stable illumination as the supply-voltage varies in the range 220–240VAC
- High efficiency > 60 lm/W
- Lamp-power factor PF = 0.60 (0.99 for 15W)
- Wide range of ambient temperatures -10 °C to +40 °C
- Type of filament: T2 (T3 for 15W)
- Number of on/off cycles ≥ 500,000 times* (150,000 times for 15W)
- Colour temperature 2700K
- Content of Hg < 2.5mg (<2mg for 15W)
- Run-up time < 1.0s (<1.2s for 15W)
- Colour-rendering index Ra ≥ 80
- Luminous flux conservation at the end of rated lifetime 70%
- Does not work with lighting dimmers
*The fluorescent lamp can be turned on and off 500,000 times (150 000 times for 15W). The number of cycles was measured in accordance with Commission Regulation (EC) No. 244/2009 of 18 March 2009.
(Fluorescent lamp on for 1 minute and off for 3 minutes)
Power [W] |
Base | Product code | Luminous flux
[lm] |
Incandescent lamp equivalent
[W] |
The time taken for the lamp to warm up to 60% of full luminous flux [s] | Input current
[mA] |
Power consumption in kWh per 1,000h | Length [mm] |
Diameter [mm] |
7.0 |
E14 | C-1407-0U | 430 | 40 | <25 | 60 | 7 | 83 |
46 |
9.0 |
E14 | C-1409-0U | 580 | 50 | <25 | 70 | 9 | 88 |
46 |
11.0 |
E14 | C-1411-0U | 740 | 60 | <25 | 85 | 11 | 94 |
46 |
13.0 |
E14 | C-1413-0U | 890 | 70 | <25 | 105 | 13 | 100 |
46 |
7.0 |
E27 | C-1707-0U | 430 | 40 | <25 | 60 | 7 | 83 |
46 |
9.0 |
E27 | C-1709-0U | 580 | 50 | <25 | 70 | 9 | 88 |
46 |
11.0 |
E27 | C-1711-0U | 740 | 60 | <25 | 85 | 11 | 94 |
46 |
13.0 |
E27 | C-1713-0U | 890 | 70 | <25 | 105 | 13 | 100 |
46 |
15.0 |
E27 | C-1715-0U | 900 | 70 | <50 | 70 | 15 | 48 |
123 |
18.0 |
E27 | C-1718-0U | 1140 | 85 | <25 | 140 | 18 | 112 |
59 |
20.0 |
E27 | C-1720-0U | 1220 | 90 | <25 | 150 | 20 | 112 |
59 |
23.0 |
E27 | C-1723-0U | 1400 | 100 | <25 | 175 | 23 | 117 |
59 |
What do I do with a defective fluorescent lamp?
Instructions for handling the remnants of the lamp if accidentally damaged
If the fluorescent lamp is broken, carefully collect the broken glass. The broken glass and other fluorescent lamp elements must not be disposed of together with other waste (e.g. municipal waste) but must be handed over to a Company which collects and recycles waste electrical or electronic equipment.
Recommendations for the end-of-life disposal of the lamp
Used or defective lamp should be handed over to a Company which recycles waste electrical or electronic equipment.